SparkQuote NEC calculators

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

Score

80

Status

Works

Tested

17 hours ago

Speed

106 ms

Why this score

  • Passed Alonzio's protocol checks
  • No key needed
  • Answers in under a second
  • Tested 14 hours ago
  • New: no confirmed outcomes yet

Details

MCP server · sparkquote.ai · Other · No key needed

How to call it

MCP (streamable HTTP): https://sparkquote.ai/mcp

Outcomes

0 delivered through Alonzio in the last 30 days · 0 confirmed · 0 paid · 0 disputed

What it offers

  • wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.
  • voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
  • watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
  • conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
  • box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
  • load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
  • ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
  • panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
  • bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
  • nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.